Tube contact sensor with pipe clamp and passive output
Description
Contact temperature sensors with clamping band and sensor block are used for temperature detection on pipes (f. e. cold and hot water) or heating pipes. With the supplied pipe clamp, the contact block is attached directly to the pipe.
Technical Data
Measuring ranges: | -30...+110°C |
---|---|
Sensors: | see table below (optional with two sensors) |
Connection type: | 2-wire connection (optional 3- or 4-wire connection) |
Testing current: | approx. 1mA |
Process connection: | Pipe clamp |
Strap dimensions: | d=13-92mm (1/4 - 3“), 300mm |
Housing: | box shaped, synthetic, white colour, 64x58x36mm |
Fitting: | M16x1,5 |
Insulating resistance: | >/= 100MOhm, by 20°C (500 VDC) |
Protection type: | IP65 according EN 60529 |
Protection class: | III according EN 60730 |
Accessiories: | Heat transfer paste |